Fluorescence-Guided Stereotactic Biopsy: A Proof-of-Concept Study

Document Type

Article

Publication Date

2-22-2019

Abstract

OBJECTIVEAccurate histopathological diagnoses are often necessary for treating neuro-oncology patients. However, stereotactic biopsy (STB), a common method for obtaining suspicious tissue from deep or eloquent brain regions, fails to yield diagnostic tissue in some cases. Failure to obtain diagnostic tissue can delay initiation of treatment and may result in further invasive procedures for patients. In this study, the authors sought to determine if the coupling of in vivo optical imaging with an STB system is an effective method for identification of diagnostic tissue at the time of biopsy.METHODSA minimally invasive fiber optic imaging system was developed by coupling a 0.65-mm-diameter coherent fiber optic fluorescence microendoscope to an STB system. Human U251 glioma cells were transduced for stable expression of blue fluorescent protein (BFP) to produce U251-BFP cells that were utilized for in vitro and in vivo experiments. In vitro, blue fluorescence was confirmed, and tumor cell delineation by fluorescein sodium (FNa) was quantified with fluorescence microscopy. In vivo, transgenic athymic rats implanted with U251-BFP cells (n = 4) were utilized for experiments. Five weeks postimplantation, the rats received 5-10 mg/kg intravenous FNa and underwent craniotomies overlying the tumor implantation site and contralateral normal brain. A clinical STB needle containing our 0.65-mm imaging fiber was passed through each craniotomy and images were collected. Fluorescence images from regions of interest ipsilateral and contralateral to tumor implantation were obtained and quantified.RESULTSLive-cell fluorescence imaging confirmed blue fluorescence from transduced tumor cells and revealed a strong correlation between tumor cells quantified by blue fluorescence and FNa contrast (R2 = 0.91, p < 0.001). Normalized to background, in vivo FNa-mediated fluorescence intensity was significantly greater from tumor regions, verified by blue fluorescence, compared to contralateral brain in all animals (301.7 ± 34.18 relative fluorescence units, p < 0.001). Fluorescence intensity measured from the tumor margin was not significantly greater than that from normal brain (p = 0.89). Biopsies obtained from regions of strong fluorescein contrast were histologically consistent with tumor.CONCLUSIONSThe authors found that in vivo fluorescence imaging with an STB needle containing a submillimeter-diameter fiber optic fluorescence microendoscope provided direct visualization of neoplastic tissue in an animal brain tumor model prior to biopsy. These results were confirmed in vivo with positive control cells and by post hoc histological assessment. In vivo fluorescence guidance may improve the diagnostic yield of stereotactic biopsies.

Publication Title

Journal of Neurosurgery

PubMed ID

30797218

Comments

This article was published in Journal of Neurosurgery, Volume 6, Issue 1.

The published version is available at https://doi.org/0.3171/2018.11.JNS18629

Copyright © 2019 AANS.

This document is currently not available here.

COinS